Setting Parameters - Toshiba TOSVERT VF-S15 Instruction Manual

My function-s
Hide thumbs Also See for TOSVERT VF-S15:
Table of Contents

Advertisement

4

Setting parameters

.
This chapter explains how to set parameters related to the My function-S using the composition
of the My function-S and the rules.
 Input terminals
Input signal terminals that can be used with the My function-S are as follows;
● Input terminals (8 terminals: F, R, RES, S1, S2, S3, VIA, VIB)
VF-S15 has 8 input terminals.
The input terminals are used for following 2 ways.
1) Input terminals to which assign multiple functionss
2) Simple ON-OFF signal input terminals like a PLC
In this manual, such input terminals are referred to as X1, X2 to X8 to distinguish them
from case 1).
● Virtual input terminals (4 terminals)
Virtual input terminals cannot be turned on and off electronically unlike actual input terminals.
Virtual input terminals can be turned on and off using communication function or My
function-S. You can assign the multiple functions as same as actual input terminals.