Dell EqualLogic PS4000 Hardware Maintenance page 14

Storage arrays
Hide thumbs Also See for EqualLogic PS4000:
Table of Contents

Advertisement

PS4000 Hardware Maintenance
Use the null modem cable shipped with the array to connect to Serial
Port 0 on the active control module (ACT LED is green) to a console or a
computer running a terminal emulator.
Make sure the serial line characteristics are as follows:
-
9600 baud
-
One STOP bit
-
No parity
-
8 data bits
-
No flow control
2. Log in to an account with read-write access, such as the
3. Enter the
shutdown
login: grpadmin
Password:
Copyright 2001-2009 Dell, Inc.
group1> shutdown
If you are using a serial connection to shut down an array, it is safe to turn off
power when the "press any key" message appears. (Pressing any key will restart
both control modules.)
If you are using a network connection, the session will be disconnected before the
array is fully shut down. Confirm that the CACT LED on each control module is
off (not lit) before turning off power to the array.
After performing array maintenance, you can turn on power to the array. When the
array restart completes, the member and volumes will be set online.
1–6
command, as shown next.
Welcome to Group Manager
Basic Array Information
account.
grpadmin

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents