Panasonic U-8ME1E81 Service Manual page 35

2way vrf system
Hide thumbs Also See for U-8ME1E81:
Table of Contents

Advertisement

3. Detailed Settings Function
Item
Item
code
Fan tap setting
(Fan tap change
in order to prevent
drop in air
discharge caused
by filter
installation)
Humidifier ON
time
(ON time per 60
seconds)
Repeat timer
switching
Timer function
change prohibit
Smudging control
Setting the Flap
Separately
* Only for 4-way
Cassette type
Setting the Flap
Separately
* Only for 4-way
Cassette type
Setting the Flap
Separately
* Only for 4-way
Cassette type
Setting the Flap
Separately
* Only for 4-way
Cassette type
N
. o
DC fan tap
operating mode
0000
Standard
High ceiling use
For low
0001
static-pressure
filter
High ceiling use
For low
static-pressure
0003
filter
For air-blocking
material
For air-blocking
0006
material
0000
No humidifier output
0001
1 second
0002
2 seconds
0058
58 seconds
0059
59 seconds
0060
Continuously ON
0000
Function disabled
0001
Function enabled
0000
Function disabled
0001
Function enabled
0000
No smudging control
Air discharge
0000
port
0001
0002
Flap
0003
(adjustment for
up-down
0004
airflow direction)
0005
0006
Setting data
Flap position during operation
Without separate setting
Swing
Move to position 1 and stay
Move to position 2 and stay
Move to position 3 and stay
Move to position 4 and stay
Move to position 5 and stay
Setting data
D
e
s
c
i r
t p
o i
n
Purpose
Standard (setting at time of shipping)
High ceiling setting 1 (with standard panel)
Ultra long-life filter, oil guard panel, ammonia
deodorizing filter, optical regenerative deodorizing
filter
High ceiling setting 2 (with standard panel)
(Antibacterial) high-performance filter (90%)
(Antibacterial) high-performance filter (65%)
Air-cleaning unit, air-cleaning unit + optical
regenerative deodorizing filter, deodorant (activated
charcoal) filter
For 3-way discharge, when discharge duct is
connected.
For 2-way discharge
Flap 1
=90
(Motor No. 4)
Flap 2
(Motor No. 2)
=91
Flap 3
=92
(Motor No. 1)
2-13
2WAY SYSTEM
Remote Controller Functions
Flap position
Electrical
1
component
box
2
Flap 4
3
(Motor No. 3)
4
5
=93
When the flap position is set to
4 or 5 and the unit is in the
cooling or dry mode, the flap
position is moved to 3 and the
operation is started.
NOTE
The flap swings during the
operation under "Setting the
Flap Separately".
At this time, the unselected flaps
are moved to the position 1 .
1
2
3
4
5
6
7
8