Fig. 4-12: Cancel Upload (Data Reception) - Siemens Sinumerik 840D sl Function Manual

Motion control information system
Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

05.07
Cancel current job

Fig. 4-12: Cancel upload (data reception)

When you choose Cancel Current Job, two functions are made available if the
Terminate Manually checkbox has been activated in the configuration dialog:
Do not accept received data:
The data is rejected.
Accept received data:
The data is accepted.
Background:
With certain controllers, you have to configure a late receive end (end of
upload x seconds after the last character has been received).
To reduce the transmission time, the upload can be terminated after the final
characters have been received. The NC data received is accepted.
Note
The dialog only appears if the Terminate Manually checkbox has been activated
in the configuration dialog. This checkbox is not normally activated, which means
that the data received is not accepted when the upload is terminated.