6 CONTROL UNIT CU310-2 PN (PROFINET)

6.1

DESCRIPTION

The CU310-2 Controller Units are designed for operation connected to a Power Module, in the blocksize or
chassis formats.
The Control Unit CU310-2 PN (PROFINET) is a control module for single drives in which the open-loop and
closed-loop control functions of the drive are implemented.
It controls the Power Modules in the blocksize format via the PM-IF interface and is mounted directly on the
Power Module.
The table shows an overview of the available interfaces on the CU310-2 PN.
Table 15 Overview of the CU310-2 PN interfaces
Type
Isolated digital inputs
Non-isolated digital inputs/outputs
Isolated digital output
Non-isolated analog input
DRIVE-CLiQ interface
PROFINET interfaces
Serial interface (RS232)
Encoder interface (HTL/TTL/SSI)
LAN (Ethernet)
Temperature sensor input
EP terminal
Measuring sockets
NOTE:
For the characteristics of interfaces and inputs / outputs refer to the manual SIEMENS S120-GH6
6.2

SAFETY INSTRUCTIONS

WARNING
Danger of fire through overheating for insufficient ventilation clearances:
It is essential that you maintain 50 mm ventilation clearances above and below the Control Unit and
Siemens S120_EN_rev06-08062017.docx
Quantity
11
8
1
1
1
2
1
1
1
1
1
3
6-1