Figure 48 – STARTER permanent saving of the changes on the software parameters
8.4.2

Alignment software versions PC-inverter

Should be observe the following notes:
If in the screen to the left side of the drive S120, referring to the Drive, or to the Control Unit some red
marks appear, it means that there are inconsistencies between the PC and the inverter. In particular:
"!!"(red) = minor inconsistencies in terms of parameters
-
" ", " "(red) = serious inconsistencies at the level of parameters or software configuration
-
It's possible to align the two systems by pressing one of two buttons
"ONLINE" to load on the inverter the software version on your PC (
version in this inverter (
settings.
If you want to change the parameters before introducing any changes, save a copy with the
current situation, which is useful for restoring. In order to create this safety copy, at first you have to
go OFFLINE via the blue button, and then you have to click Project>Save and create a copy , giving
an appropriate name to the saved copy
On the right screen, on the expert list or user list, the values highlighted in green are the only
adjustable parameters, while those in yellow are only the current values and cannot be changed.
At the bottom of the screen are displayed details and further information. In particular, it is possible to
reset ALARM or WARNINGS, by pressing the appropriate button, once you select the tab of the item
ALARMS among those available at the bottom and after clicking on the description of interest.
Siemens S120_EN_rev06-08062017.docx
),depending on of what is believed to be the more correct version of the
next to the yellow button
), or to transfer to the PC the
8-14