Error Code 48
Unable to Print 48
Head flat cable detected to be not correctly inserted.
Step
1
Head flat cable connection
failure
2
Carriage flat cable connection
failure
3
Carriage PCB defective
4
Head defective
5
Main PCB defective
Error Code 49
Unable to Print 49
Head voltage does not raise.
User Check
- They may occur due to lower surrounding temperature. Use in warmer surrounding
temperature.
Step
1
Head flat cable connection
failure
2
Carriage flat cable connection
failure
3
Carriage PCB defective
4
Head defective
5
Power supply PCB defective
6
Main PCB defective
Cause
Reconnect the head flat cable.
Reconnect the carriage flat cable.
Replace the carriage PCB ASSY.
Replace the head/carriage unit.
Replace the main PCB ASSY.
Cause
Reconnect the head flat cable.
Reconnect the carriage flat cable.
Replace the carriage PCB ASSY.
Replace the head/carriage unit.
Replace the power supply PCB ASSY.
Replace the main PCB ASSY.