Troubleshooting; A.2 Troubleshooting - Siemens SIMATIC IFP Basic Series Operating Instructions Manual

Industrial flat panels
Table of Contents

Advertisement

A.2

Troubleshooting

Ethernet Monitors
Error pattern
The host cannot provide the
correct name and resolution
list of IFP Basic when you only
use VGA port.
The host cannot display cor-
rectly.
IFP Basic
Operating Instructions, 03/2019, A5E46178354 - AB
Possible cause
Make sure that you
insert the VGA port
correctly.
Make sure that you
select IFP Basic sup-
ported resolution.
Technical Support

A.2 Troubleshooting

Possible remedy
Unplug the VGA port and wait until "Pow-
er saving" is displayed on the monitor.
Then plug the VGA port again.
When you plug the VGA port, pay atten-
tion to the following tips.
1. Insert the VGA port to the end.
2. Make sure you insert the VGA port
vertically.
3. Tighten the screw to lock the VGA
port into place.
Select the IFP Basic supported resolution:
12.1''
1280 x 800, @60Hz
1280 x 720, @60Hz
1024 x 768, @60Hz
800 x 600, @60Hz
15.6'' and 18.5"
1366 x 768, @60Hz
1280 x 720, @60Hz
1024 x 768, @60Hz
800 x 600, @60Hz
21.5"
1920 x 1080, @60Hz
1600 x 900, @60Hz
1400 x 1050, @60Hz
1280 x 1024, @75Hz
1280 x 960, @75Hz
1280 x 800, @60Hz
1280 x 720, @60Hz
1152 x 864, @75Hz
1024 x 768, @60Hz
800 x 600, @60Hz