Kenwood NXR-700 Service Manual page 33

Vhf digital base-repeater
Hide thumbs Also See for NXR-700:
Table of Contents

Advertisement

Pin No.
Name
I/O
13
INRA_SW
-
No connection
14
NC
-
No connection
15
HOOK_RXD_SCM
I
Hook detection input
Power source control of audio power
16
AMP_SW
O
amplifi er
17
SCM_EN
-
No connection
18
AF_MUTE
O Audio mute control
19
INSP_SW
-
No connection
Serial data to DAC
20
EVOL_DATA
O
(for audio level adjustment)
21
PTT_AM16C
I
"Press-to-talk-switch" signal to Main MPU
Serial clock to DAC
22
EVOL_CLK
O
(for audio level adjustment)
23
GND
-
Ground
Serial load to DAC
24
EVOL_LD
O
(for audio level adjustment)
25
TAAD_SW
O Route formation signal of audio circuit
26
TA_SW
O Route formation signal of audio circuit
27
BEEP_SW
O Route formation signal of audio circuit
28
PATH_SW
O Route formation signal of audio circuit
29
RXAD_SW
O Route formation signal of audio circuit
30
MIC_SW
O Route formation signal of audio circuit
31
MICAD_SW
O Route formation signal of audio circuit
32
TD_SW
O Route formation signal of audio circuit
33
NC
-
No connection
34
LO_VOL_DET
I
Detection of voltage for low voltage state
35
GND
-
Ground
36
PTT_TXD_SCM
-
No connection
CN402 (To X53-413 CN2)
1
HI_VOL_DET
I
Voltage monitor
2
GND
-
Ground
3
50MPU_A_GND
-
Ground
4
50MPU
I
5V constant voltage
5
50MPU_A_GND
-
Ground
6
DC50
I
5V constant voltage
7
DC50
I
5V constant voltage
8
DC50
I
5V constant voltage
9
DC50
I
5V constant voltage
10
33MPU_A_GND
-
Ground
11
33MPU
I
3.3V constant voltage
12
33MPU
I
3.3V constant voltage
13
33MPU_A_GND
-
Ground
14
50MPU_A
I
5V constant voltage
15
33MPU_A
I
3.3V constant voltage
TERMINAL FUNCTION
Function
Pin No.
Name
I/O
16
33SH
O 3.3V constant voltage
17
50MPU_CONT
O 5V regurator control
18
NC
-
No connection
"External press-to-talk-switch" signal
19
E_PTT_SH
I
to Main MPU
20
SC_SH
I
"Squelch control" signal to Main MPU
21
GND
-
Ground
UART signal from RF control MPU to
22
SRXD_ATXO
O
Main MPU
UART signal from Main MPU to RF
23
STXO_ARXO
I
control MPU
24
GND
-
Ground
25
RF_PTT
I
"Press-to-talk-switch" signal to Main MPU
"During the transmission" signal to
26
TX_STATE
I
Main MPU
27
QT_DQT
I
"Detect QT or DQT" signal to Main MPU
"Detect accident of RF block" signal to
28
RADIO_EER
I
Main MPU
29
GND
-
Ground
"Frequency shift" signal to Analog
30
ADSP_CK_SFT
O
mode DSP
31
TRUKING
I
"Trunking mode" signal to Main MPU
32
A16C_CK_SFT
O "Frequency shift" signal to RF control MPU
33
BER_DAT
O Serial data for measurement bit error rate
34
BER_CLK
O Serial clock for measurement bit error rate
35
GND
-
Ground
System reset signal from modem con-
36
SYS_RST
O
trol MPU
CN713 (To COM D-sub 9-pin connector)
1
CD
-
No connection
2
DSR
I
Data Set Ready
3
RD
I
Receive Data
4
RTS
O Request to Send
5
SD
O Send Data
6
CTS
I
Clear to Send
7
DTR
O Data Terminal Ready
8
RI
-
No connection
9
GND
-
Ground
RX Unit (X55-3092-72)
Pin No.
Name
I/O
CN5 (To RX ANT)
1
RX_SIGNAL
I
Receive signal input (Coaxial)
CN41
1
MONITOR_PORT
O Use for RX BPF tuning (Coaxial)
NXR-700