Kenwood NXR-700 Service Manual page 86

Vhf digital base-repeater
Hide thumbs Also See for NXR-700:
Table of Contents

Advertisement

NXR-700
Item
Condition
15. High
1) Center
Transmit
Power
(Pre ADJ)
16. Coupler
1) Center
ADJ
17. High
1) Center
Transmit
Power
(Max power
limit ADJ)
18. High
Frequency
Transmit
1) Low
Power
2) Center
3) High
Attach the EXCITER/FINAL
shield cover.
19. Low
Frequency
Transmit
1) Low
Power
2) Center
3) High
Attach the EXCITER/FINAL
shield cover.
20. Deviation
Modulation pattern
: 100Hz square signal
(The transmis-
Connect the deviation meter to
sion VCO band
the TX ANT end via the ATT.
is separated
Deviation meter setting
into A and B.
HPF: OFF
3-points for
LPF: 15kHz
each, i.e., total
De-emp: OFF
of 6-points shall
Detector: (p-p)/2
be adjusted.)
1) A: Low
2) A: Center
3) A: High
4) B: Low
5) B: Center
6) B: High
Exit "Deviation" screen to "Test
Mode" screen, then set test
signaling mode to be "NXDN"
and signaling number to be "3".
Set Wide/Narrow drop down list
to be "Narrow". Set test channel
to be "1".
Deviation meter setting
HPF: OFF
LPF: 15kHz
De-emp: OFF
Detector: +peak, –peak
Push "Transmit" button, then
measure the deviation.
86
ADJUSTMENT
Measurement
Test-
Unit
Terminal
equipment
Power meter
Rear
TX ANT
PC
DVM
Final
REF
Power meter
Power meter
Rear
TX ANT
PC
Power meter
Rear
TX ANT
Ammeter
Deviation
Rear
TX ANT
meter
Oscilloscope
PC
Adjustment
Unit
Parts
Method
PC
Value: 1024
ADJ
Final
VR2
25W
Final
VR1
Adjust to the mini-
mum value.
PC
Value: 1024
ADJ
Final
VR2
30.0W
PC
25.0W
ADJ
5.0W
PC
±1.10kHz
ADJ
Adjust it into clean
square wave with
changing "Sub-
audible Gain" and
"Audible Gain".
Check
Specifi cations / Remarks
Fixed value writing
±0.5W
Fixed value writing
±1.0W
±0.5W
10.0A or less
±0.1W
5.5A or less
±0.05kHz
Connect the deviation me-
ter to the TX ANT end via
the ATT.
±3.06kHz±0.20kHz
Clean sine wave.