3.4.1 Setting the Module Address

Each IP 244 temperature controller module requires 32 addresses for transferring the required
parameters. You only need to set the start address of the module. The following 31 addresses
are then automatically occupied and no longer available for other modules. The addresses can
be set in steps of 32.
DIL switch A 76
for ADB 8 to 11
Example:
you wish to assign the start address n = 160 in the normal I/O area P of the central controller.
The switches must then be set as shown below:
2–32
DIL switch A 77
for ADB 5 to 7
IP244
C79000–B8576–C859–02