4.6

Installing Control Unit

Plugging the Control Unit onto an IP20 Power Module FSA ... FSF
Procedure
Proceed as follows to plug the Control Unit
onto a Power Module:
1. Locate the lugs at the rear of the Control
Unit in the matching recesses of the
Power Module.
2. Press the Control Unit onto the Power
Module until you hear it latch into place.
You have now plugged the Control Unit onto the Power Module.
To remove the Control Unit, press on the release button on the Power Module and withdraw
the Control Unit.
Plugging the Control Unit onto a PM330 Power Module
To plug the Control Unit onto a PM330 Power
Module, you must open the left-hand housing
flap of the Power Module.
Press the release button on the Power Mod-
ule to withdraw the Control Unit.
Converter with CU230P-2 Control Units
Operating Instructions, 04/2015, FW V4.7 SP3, A5E34257946B AB