3.1.3 Module Installation and Removal
This section explains how to install and remove a power supply module, PLC CPU module, CNC CPU
module, input/output module and intelligent function module or another module to and from the base unit.
Module installation and removal to/from Q3
Installation
(1) Insert the module fixing hook into the module fixing hole of the base unit.
(B)
(C)
(A) Base unit
(B) Module connector
(C) Module fixing hook
(D) Module fixing hole
(E) Module
(2) Push the module in the direction of arrow to install it into the base unit.
(3) Make sure that the module is installed in the base unit correctly.
(4) Fix the unit with screws on the base unit.
(Note)
Be sure to fix all the modules with screws to prevent them from dropping.
The fixing screws (M3 x 12) are to be prepared by user.
For CNC CPU module, use the attached fixing screws (M3 x 13).
□
(A)
(E)
(D)
□
DB, Q6
B
(A)
(C)
(D)
C70 Connection Manual
3.1 Module Installation
(E)
61