4.10 Connecting the I/O Extension Connector Unit
Connect a relay cable to GT15-DIOR external input/output unit for GOT1000 series for the connection of I/O
extension connector unit(FCU7-HN831).
FCU7-HN831
<CNX1>
Input 32 points
(Configure with the
common 1 pin for
CNX1
signal 8 pins)
COM0
COM1
COM0
COM1
24VDC
<CNX2>
Input 32 points
(Configure with the
common 1 pin for
CNX2
signal 8 pins)
COM2
COM3
COM2
COM3
24VDC
*24VDC input wiring
can supply to CNX1
without using DCIN
connector. (In this case,
make sure to wire more than 2 pins.)
(Note)
Make sure to install FCU7-HN831 unit in the same panel as GOT. Separate FCU7-HN831 unit
from the drive line or power line when wiring.
GT15-DIOR
H810
H810 cable
I/O extension connector unit
(FCU7-HN831)
GOT-DIO
CNY1
L
L
L
L
L
L
L
L
L
L
L
L
L
<CNY1>
Output 16 points
L
(Configure with the common
L
1 pin for signal 4 pins)
RUN output 1 point is
L
included (with dedicated
common).
F
L
*RUN output is built-in
fuse(poli-switch)
*Supply 24VDC power before
24VDC
DCIN
starting up GOT. If it is
supplied after starting up
GOT, it will not operate.
FG
C70 Connection Manual
4.10 Connecting the I/O Extension Connector Unit
GOT1000
GT15 external input/output unit
(GT15-DIOR sink input/source output type)
Internal
R
control
circuit
XD00
R
XD01
Scan input circuit
XD02
XD03
XD04
XD05
XD06
XD07
XD08
XD09
XD0A
XD0B
XD0C
XD0D
XD0E
XD0F
Internal
control
circuit
XSCN00
R
XSCN01
Scan output circuit
XSCN02
XSCN03
XSCN04
XSCN05
XSCN06
XSCN07
Internal
control
circuit
YD00
R
YD01
Source output circuit
YD02
YD03
YD04
YD05
YD06
YD07
YD08
YD09
YD0A
YD0B
YD0C
YD0D
YD0E
YD0F
RUN
24VDC
External
Constant
supply
-voltage
power off
circuit
0V
detection
81