When using as a safety device for a press machine or paper shearing machine in Japan
(Applicable model: SF4D-□-01)
<Japanese regulations>
Standards for safety device mechanisms for press machines and shearing machines.
This device has passed, as indicated below, the "Type Examination" based on Arti-
cle 44, 2 of the Industrial Safety and Health Law of Japan.
When using as a safety device for a press machine or paper shearing machine in
Japan, always attach the protective tube SFPD-A10 (option) to the cable. The
safety device cannot be used for a press machine or shearing machine unless a
protective tube is attached to the cable.
<Type Examination Numbers>
Model No.
Safety light curtain
Specified control unit
SF4D-F□-01, SF4D-H□-01
-
SF4D-A□-01
-
SF4D-F□-01, SF4D-H□-01
SF-C11
SF4D-A□-01
SF-C11
SF4D-F□-01, SF4D-H□-01
SF-C13
SF4D-A□-01
SF-C13
● Type Examination Numbers TA601 (press machine) and TA603 (shearing ma-
chine) are indicated on SF4D-F□-01 units and SF4D-H□-01 units, and Type
Examination Numbers TA600 (press machine) and TA602 (shearing machine)
are indicated on SF4D-A□-01 units.
● When only this device is used, or when this device is used in combination with
the specified control unit, a different Type Examination Number applies. When
used in combination with the specified control unit, the Type Examination Num-
ber is indicated on the control unit.
● When used in combination with the specified control unit, this device cannot be
used for a shearing machine.
3
CONFIRMATION OF PACKED OBJECTS
Main body: emitter and receiver
Test Rod
SF4D-F□(-01): SF4B-TR14 (ø14 × 220mm)
SF4D-H□(-01): SF4B-TR25 (ø25 × 220mm)
Quick Instruction Manual (Japanese, English, Chinese, Korean) 1 pc. for each language
General Information for Safety, Compliance, and Instructions (23 languages) 1 pc.
4
NAMES AND FUNCTIONS OF INDICATORS
Upper application indicator
Lower application indicator
Emitter: Light emission intensity control indicator
Receiver: Function setting indicator
Emitter: Test indicator
Receiver: Interlock indicator
Emitter: Operation indicator
Receiver: OSSD indicator
● Emitter / receiver common
Name
Line synchronization
<When beam axis alignment mode is set>
Upper application indicator
Control output (OSSD 1 / 2) ON: Lights blue, When top end beam channel receives
(Blue / Red / Green / Orange)
light: Lights red, When top end beam channel is blocked: Turns OFF
<When beam axis alignment mode is set>
Lower application indicator
Control output (OSSD 1 / 2) ON: Lights blue, When bottom end beam channel re-
(Blue / Red / Green / Orange)
ceives light: Lights red, When bottom end beam channel is blocked: Turns OFF
When light reception is stable: Lights green
Stable light reception indicator
When light reception is unstable: Lights orange
(Green / Orange)
When light is blocked: Turns OFF
Received light
Light intensity / Level 3: Lights green "3", Light intensity / Level 2: Lights green "2"
intensity (Green)
Light intensity / Level 1: Lights green "1", When light is blocked: Turns OFF
Digital indicator
Error (Yellow)
Normal operation: Turns OFF, Error: Number blinks or lights yellow "0"
(Green / Yellow)
Polarity
When PNP output is set: Lights yellow "P" (only during startup)
(Yellow)
When NPN output is set: Lights yellow "n" (only during startup)
Frequency indicator (Orange)
● Emitter
Name
Line synchronization
Light emission intensity control
Short mode: Turns OFF, Long mode: Lights orange
indicator (Orange)
Test indicator (Orange)
During test: Lights orange, Normal operation: Turns OFF
Operation indicator
Control output (OSSD 1 / 2) OFF: Lights red
(Red / Green)
Control output (OSSD 1 / 2) ON: Lights green
● Receiver
Name
Line synchronization
Communication module connected: Blinks orange
Function setting indicator (Orange)
Blanking function or parallel connection used: Lights orange (Applicable model: SF4D-□) (Note)
Interlock indicator (Yellow)
Interlock activated: Lights yellow, All other times: Turns OFF
Control output (OSSD 1 / 2) OFF: Lights red
OSSD indicator (Red / Green)
Control output (OSSD 1 / 2) ON: Lights green
Note: For details on the blanking function and parallel connection, refer to "SF4D Series Instruction Manual".
WARNING
Type Examination Number
Press machine
Shearing machine
TA601
TA600
TA605
TA604
TA607
TA606
Upper application indicator
Lower application indicator
Stable light
reception indicator
Digital indicator
Frequency indicator
Function
Optical synchronization
When frequency 1 is set: One indicator lights orange
-
When frequency 2 is set: Two indicators light orange
Function
Optical synchronization
Normal operation: Lights green
Error: Lights red
Function
Optical synchronization
5

DIP SWITCH SETTINGS

For detailed information on the functions of the device, refer "our web site:
panasonic.net/id/pidsx/global
● DIP Switch Settings
<Changing settings using the DIP switches>
Item
DIP switch 1 / 2
(Emitter / Receiver)
Synchronization
method
TA603
TA602
-
-
-
-
DIP switch 3
(Emitter)
Light emission
intensity control
function
DIP switch 3
(Receiver)
Indicator selector
One for each
1 piece
DIP switch 4
(Emitter / Receiver)
Power save mode
Make sure that the power is OFF when setting DIP switch 1 / 2 (emitter / receiver)
and DIP switch 3 (emitter). If DIP switch settings are changed while the power is
ON, the settings will not be reflected. The settings will be reflected after the power
is turned OFF and then turned back ON.
● Remove the indicator cover from the device to access the DIP switches.
M2.6 screw (length 7mm)
● After setting the DIP switches, always reattach the indicator cover on the device.
Tighten to a torque of 0.3N·m or less.
● There is packing on the indicator cover. If the packing is not fitted on the cover
properly, fit as shown below before attaching to the device.
".
Description
Settings and ranges, indicator
Line synchronization
• DIP switch 1: OFF
• DIP switch 2: OFF
Frequency indicator (orange): Turns OFF
Optical synchronization, Frequency 1
• DIP switch 1: ON
• DIP switch 2: OFF
Selects the synchronization method.
Frequency indicator (orange):
When optical synchronization is se-
lected, you can set a different fre-
Optical synchronization, Frequency 2
quency to reduce mutual interfer-
• DIP switch 1: OFF
ence.
• DIP switch 2: ON
Frequency indicator (orange):
Line synchronization
• DIP switch 1: ON
• DIP switch 2: ON
Frequency indicator (orange): Turns OFF
Short mode
Sensing range
SF4D-F□(-01): 0.2 to 7m
SF4D-H□(-01), SF4D-A□(-01):
• DIP switch 3: OFF
Light emission intensity control
indicator (orange): Turns OFF
Controls the light from the emitter for
the change of sensing range.
Long mode
Sensing range
SF4D-F□(-01): 0.8 to 12m
SF4D-H□(-01), SF4D-A□(-01):
• DIP switch 3: ON
Light emission intensity control
indicator (orange): Lights
Beam axis alignment mode
The upper application indicator and
• DIP switch 3: OFF
lower application indicator can be
used as an beam axis alignment
Application mode
mode or an application mode.
• DIP switch 3: ON
Normal mode
(Allows illumination of some indicators)
• DIP switch 4: OFF
Power save mode
Turns OFF the indicators reduce
(Upper application indicator and
power consumption.
lower application indicator, digital
indicator / received light intensity
are always turns OFF)
• DIP switch 4: ON
CAUTION
This device
Indicator cover
CAUTION
https://
Factory default setting
One indicator lights
Line synchronization
Two indicators light
0.2 to 9m
Short mode
0.8 to 15m
Beam axis alignment
mode
Normal mode
<DIP switches>
ON
OFF
4
3
2
1

Advertisement