The buffer memory is used to exchange data between the RJ71EIP91 and the CPU module or EtherNet/IP devices. Buffer
memory values are set to their defaults (initial values) when the system is powered off or the CPU module is reset.

List of buffer memory addresses

Address (decimal)
0 to 16628
16629
16630
16631
16632
16633
16634
16635
16636 to 16639
16640 to 16895
16896 to 17151
17152 to 25732
25733 to 25735
25736 to 25855
25856 to 26111
26112 to 26367
26368 to 27007
27008 to 27023
27024 to 27039
27040 to 27055
27056 to 27135
27136 to 27151
27152 to 27167
27168 to 27183
27184 to 27391
27392 to 27647
27648 to 27903
27904
27905
27906 to 27907
27908
27909
27910
27911
27912 to 28159
APPX
142

Appendix 3 Buffer Memory

Buffer Memory
Address
Name
(hexadecimal)
0H to 40F4H
System area
40F5H
Block assurance specification per connection
40F6H
Block assurance state per connection
40F7H
Application Trigger operating
specification (Class1)
40F8H
40F9H
System area
40FAH
EtherNet/IP data link continuation
specification
40FBH
40FCH to 40FFH
System area
4100H to 41FFH
Class1 I/O data size
4200H to 42FFH
4300H to 6484H
System area
6485H to 6487H
Setting status
6488H to 64FFH
System area
6500H to 65FFH
Class1 I/O data start offset
address
6600H to 66FFH
6700H to 697FH
System area
6980H to 698FH
Application Trigger (Class1)
6990H to 699FH
69A0H to 69AFH
69B0H to 69FFH
System area
6A00H to 6A0FH
Class1 communication status
6A10H to 6A1FH
6A20H to 6A2FH
6A30H to 6AFFH
System area
6B00H to 6BFFH
Class1 Connection Behavior Error status
6C00H to 6CFFH
System area
6D00H
PING test request area
6D01H
6D02H to 6D03H
6D04H
PING test result area
6D05H
6D06H
6D07H
6D08H to 6DFFH
System area
Application Trigger operating
specification request
Application Trigger operating
specification state
EtherNet/IP data link continuation
specification request
EtherNet/IP data link continuation
specification state
Class1 Input data length
Class1 Output data length
MAC Address
Class1 Start offset address to the
input data
Class1 Start offset address to the
output data
Application Trigger Request
(Class1)
Application Trigger Acceptance
(Class1)
Application Trigger Completion
(Class1)
Data link status (Class1)
Error status (Class1)
Reserved station (Class1)
Communication time check
Transmission count
IP Address
Result
Total Number of packet
transmissions
Number of success
Number of failure
Initial
Read, write
value
Setting
Read, write
*1
value
0
Read
0
Read, write
0
Read
0
Read, write
0
Read
0
Read
0
Read
Setting
Read
value
65535
Read
65535
Read
0
Read, write
0
Read
0
Read
0
Read
0
Read
0
Read
0
Read
0
Read, write
0
Read, write
0
Read, write
0
Read
0
Read
0
Read
0
Read