6.10.4.4

AP RADIUS Authenticator

Note
This WBM page is only available in access point mode.
Configuration of the RADIUS server
On this WBM page, you define the RADIUS servers and the RADIUS authentication of the
access point. You can enter data for two RADIUS servers.
Description
The page contains the following boxes:
● Reauthentication Mode
Specify who sets the time after which the clients are forced to reauthenticate.
– - (disabled)
– Server
– Local
● Reauthentication Interval [s]
If time management is local, enter the period of validity of the authentication in seconds. The
minimum time is 1 minute (enter 60), the maximum time is 12 hours (enter 43200). The
default is one hour (3,600 seconds).
The table has the following columns:
● Server IP Address
Enter the IP address or the FQDN (Fully Qualified Domain Name) of the RADIUS server.
● Server Port
Here, enter the input port on the RADIUS server.
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C485-03
Reauthentication mode is disabled.
Enables time management on the server.
Enables local time management. In "Reauthentication Interval", specify the time of
validity.
Configuring with Web Based Management