Synchronizing to the Mains
A separate connection is necessary that the HMV01.1R may be operated
synchronously to the mains. The synchronizing voltage must be tapped
before the mains choke KDxx but after the mains filter. Power and
synchronizing voltage connection must be in phase (see figure below).
The synchronizing voltage must be connected to the control voltage inlet
(X14) of the HMV01.1R.
L1
Combining filter HFD
L2
L3
L1.1
L2.1 L3.1
Q1
KDxx
X3
L1
L2
1)
Use a motor circuit-breaker (F2; e.g. PKZM6.3) or fuses (6.3 A) to
protect X14.
Fig. 13-12:
Synchronizing voltage HMV01.1R
Details of the Mains Choke
The mains chokes are equipped with a temperature contact which opens
at T = 150 °C (connections a - b). The contact can be evaluated by a
controller and is used for example for a regulated shutdown of the unit,
should the control cabinet cooling fail.
Note:
Technical data of mains chokes: see page 13-17
Details of the Combining Filter
When operating combining filters at grounded IT mains, the type of
construction causes leakage currents that may cause possibly existing
circuit breakers or voltage monitors to trip. Remedy: Install an isolating
transformer.
Note:
Technical data of HFD filters: see page 13-19
F2
connection must be
phase coincident