Electrical Data; Hmv01.1E-W0030, -W0075, -W0120 - Bosch Rexroth IndraDrive HMV01.1E-W0030 Project Planning Manual

Supply units
Hide thumbs Also See for Rexroth IndraDrive HMV01.1E-W0030:
Table of Contents

Advertisement

Rexroth IndraDrive
7.3

Electrical Data

HMV01.1E-W0030, -W0075, -W0120

Designation
kind of connection (mode of operation at
the mains)
mains input voltage (rated voltage)
transient overvoltage limit values
mains frequency
Maximum mains frequency change per
time unit
mains input continuous current (r.m.s.
value)
connected mains power without DC bus
choke (at max. DC bus power)
connected mains power with DC bus
choke (at max. DC bus power)
power factor (cosϕ)
DC bus voltage (range)
upper DC bus voltage limit (shutdown
2)
threshold)
lower DC bus voltage limit (shutdown
3)
threshold)
continuous DC bus power (at U
4)
with choke
continuous DC bus power (at U
without choke
continuous DC bus power depending on
mains input voltage
peak DC bus power
(for max. 0,3 s with a preload of
0,6 x I
and 40 °C ambient
LN cont
temperature)
braking resistor switch-on threshold
continuous brake power
maximum brake power
brake energy absorption
DC bus capacity
overload capacity
factor / duration
power dissipation
DOK-INDRV*-HMV-*******-PR01-EN-P
Symbol
-
U
LN
U
L trans max
f
LN
df
/t
LN
I
LN cont
S
LN
1)
S
LN (L_DC)
cosϕ
U
DC
U
DC limit (max)
U
DC limit (min)
=400V)
P
LN
DC cont
=400V)
P
LN
DC cont
P
DC peak
U
DC (R_DC On)
C
DC
I
out_max1/
I
out_cont1
P
Diss
These data refer to a supply impedance of 40 µH.
1)
2)
When the upper DC bus voltage limit has been reached, the supply unit does
not switch off. The display shows a warning message. The output stages of
the drive controllers are locked.
3)
When the lower DC bus voltage limit has been reached, the supply unit does
not switch off. The display shows a warning message. At an undervoltage of
0,75 * U
4)
Inductance of the choke:
HMV01.1E-W0030: 400 µH
HMV01.1E-W0075: 200 µH
HMV01.1E-W0120: 100 µH
Fig. 7-3:
Technical data
Unit
HMV01.1E-W0030
-
V
380 -10% to 480 +10%
V
Hz
Hz/s
A
50
kW
18
kW
30
-
V
V
V
kW
30
kW
18
at U
< 400 V: 1% power reduction per 4 V
LN
at U
> 400 V: 1% power increasing per 4 V
LN
kW
45
V
variable 80V +
kW
1,5
kW
36
kWs
100
µF
1410
A
(related to rated power without DC bus choke)
W
150
the supply unit switches off.
LN
Electrical Installation
HMV01.1E-W0075
HMV01.1E-W0120
3-phase
1200
48 to 62
2% * f
LN
125
45
75
1
435 to 710
900
¥
0,75 *
2 * U
LN
75
45
112
constant 820V or
¥
2 * U
LN
2
90
250
3760
5640
factor 2,5
340
7-7
200
72
120
120
72
180
2,5
130
500
500