Guidelines And Declarations - Siemens IFP1900 INOX PRO Compact Operating Instructions

Hide thumbs Also See for IFP1900 INOX PRO:
Table of Contents

Advertisement

Specifications

6.2 Guidelines and declarations

ATEX/IECEx approval
Special conditions of use
The SIMATIC Industrial Flat Panel with article number 6AV7484-6AB..-0AA0 including the
top side of the stand provides a degree of protection of at least IP66. The bottom side of the
stand shall be connected to a certified enclosure, providing a degree of protection of at least
IP54 according to IEC 60079-15 for gas and non-conductive dust and IP6X according to IEC
60079-31, for conductive dust, taking into account the environmental conditions under which
the equipment is used.
The equipment shall be installed in such a way that the risk of mechanical danger is low.
To avoid an electrostatic charge, wipe the enclosure surface with a damp cloth only.
When used in an area requiring the use of equipment with EPL Gc:
● The equipment shall only be used in an area of not more than pollution degree 2, as
defined in EN 60664-1.
● Provisions shall be made to prevent the rated voltage from being exceeded by transient
disturbances of more than 119 V.
Under the special conditions mentioned, the following approvals apply to the device:
● II 3 G Ex nA IIC T4 Gc and
II 3 D Ex tc IIIC T70 ºC Dc
ATEX certificate number: DEKRA 16ATEX0045X
Standards: EN 60079-0:2012 +A11:2013, EN 60079-15:2010, EN 6007931:2014
● Ex nA IIC T4 Gc and
Ex tc IIIC T70 ºC Dc
IECEx certificate number: DEK 16.0021X
Standards: IEC 60079-0:2011 (Ed.6), +Corr.1. 2012 +Corr.2. 2013, IEC 60079-15:2010
(Ed. 4), IEC 60079-31:2013 (Ed. 2)
6.2
Guidelines and declarations
Notes on CE marking
This product meets the requirements and safety objectives of the EMC directive 2014/30/EU
(EMC Directive), and is designed for operation in the following fields of application according
to this CE marking:
Field of application
Industrial area
26
Requirement for emissions
EN 61000-6-4:2007 +A1:2011
Compact Operating Instructions, 07/2019, A5E35751632-AC
Requirement for interference immunity
EN 61000-6-2:2005
IFP1900 INOX PRO