Performance Tests
SDH Transmit/Receive Jitter Amplitude Accuracy
46 Select
TRANSMIT
Pattern is set to OFF.
.
47 Check the Optical Power measurement Results and adjust the Optical
Attenuation as necessary for Received optical power within the BER & JITTER
range. Record the Optical power reading.
and ensure Jitter is set to OFF and Calibration
JITTER
3-113