HP 37718A Installation And Verification Manual page 154

Hide thumbs Also See for 37718A:
Table of Contents

Advertisement

Performance Tests
SDH Transmit/Receive Jitter Amplitude Accuracy
STM-1 Optical
48 Repeat steps 6 to 43 using the information in the Table below for STM-1 Optical
Rate.
STEP
TX
RX
Range
Range
6-8
OFF
1.6UI
9
OFF
1.6UI
13-15 20
1.6UI
16-20
22-25
27-31
16UI
33-37
39-43 50
64
3-114
RX
Tx
Tx
Filter
UI p-p
Freq
LP+HP2 OFF
OFF
LP+HP1 OFF
OFF
LP+HP1 0.2
65 kHz 0.15
LP+HP2
650 kHz 0.15
LP+HP1 0.91
6.5K
3.52
4K
7.52
2.5 kHz 7.10
FIXED
33
50Hz
TX Result
TX Result
RX Result
MIN p-p
MAX p-p
MIN p-p
OFF
OFF
N/A
OFF
OFF
N/A
0.25
0.136
0.25
0.134
0.82
1.00
0.796
3.30
3.74
3.174
7.94
6.756
30.82
35.18
28.35
RX Result
MAX p-p
0.050
0.050
0.264
0.266
1.024
3.866
8.164
37.65

Hide quick links: