17
en | Operating Commands
Control Panel
Fault Descriptions
1 System Fault
A system fault only displays when any of the following faults occur. After entering Fault
Analysis Mode, press and hold the [1] key to determine which of the following faults occurred.
Low Battery Fault – A low battery fault registers when the system detects a low capacity
back-up battery. The system automatically performs a battery test every four hours and every
time you arm the system.
Date and Time – The date and time fault registers every time the system is powered down.
RF Receiver Fail – The RF receiver fault registers once the system detects that the wireless
receiver unit is disconnected, tampered or jammed.
Output 1 to 3 Fail – This fault registers when the system detects any output is disconnected.
This fault clears once any output is reconnected. Your installer must program the system for
this feature to operate.
Telephone Line Fail – A telephone line fault registers when the system detects that the
telephone line is disconnected from the control panel. Your installer must program the system
for this feature to operate.
Power Supply Fail – This fault occurs when AUX power supplies fails, +12V power fails, or
SDI2 Bus power fails. Contact your installer as soon as this fault displays.
Tamper – This fault occurs when the system detects the control panel is tampered.
RF Repeater Fail – The RF repeater 1 to 8 fault registers once the system detects that the
wireless repeater is disconnected, tampered or jammed.
2 RF Low Battery
This fault occurs when any of the RF wireless devices report a low battery condition to the
control panel. While in Fault Analysis Mode, press and hold the [2] key until two beeps sound.
This displays the zone reporting the RF Low Battery fault.
3 Zone Tamper Fail
This fault occurs when any zone with tamper becomes an open circuit. Press and hold the [3]
key until two beeps sound. This displays the zone reporting the tamper fail fault.
4 Sensor Watch Fault
A sensor watch fault registers because one or more detection devices failed to detect any
movement during the disarmed state for the time period programmed by your installer. The
fault clears once the zone in question detects movement and resets. Press and hold the [4]
key until two beeps sound. This displays the zone reporting the sensor watch fault.
5 RF Sensor Watch
An RF sensor watch fault registers because one or more RF detection devices fails to
communicate to the RF radio receiver for the time period programmed by your installer. The
fault clears once the RF device in question successfully transmits to the RF radio receiver.
Press and hold the [5] key until two beeps sound. This displays the RF detection device
reporting the RF sensor watch fault.