Swinger Programming; Swinger Shutdown Count For Siren - Bosch ICP-SOL2-P Quick Reference Manual

Hide thumbs Also See for ICP-SOL2-P:
Table of Contents

Advertisement

Control Panel
Item
Zone Options 1
Zone Options 2
Zone Dialer Options
Keyswitch Zone Options
Table 4.2: Zone Item Options
The keyswitch zone options replace Zone Options 1 only for the zones that were programmed
to operate as a keyswitch zone.
4.7

Swinger Programming

4.7.1

Swinger Shutdown Count For Siren

Item
Swinger Shutdown Count
For Siren
Bosch Security Systems, Inc.
Option
0 = 0.5 sec.
1 = 1 sec.
2 = 2 sec.
3 = 3 sec.
4 = 4 sec.
5 = 5 sec.
6 = 10 sec.
7 = 15 sec.
1 = Lockout siren/dialer
2 = Delay alarm report
4 = Silent alarm
8 = Sensor watch
1 = Isolated in STAY Mode 1
2 = Zone isolation allowed
4 = Forced arming allowed
8 = Zone Restore Report allowed
0 = No zone reports allowed
1 = Report to Receiver 1
2 = Report to Receiver 2
4 = Report to both Receiver 1 and Receiver 2
8 = Report to Receiver 2 only if Receiver 1 fails
0 = Latching arm and disarm in AWAY Mode
1 = Latching arm in AWAY Mode
2 = Latching disarm from AWAY Mode or STAY Mode
4= Latching arm and disarm in STAY Mode
5 = Latching arm in STAY Mode
6 = Latching disarm from STAY Mode
8 = Momentary arm and disarm in AWAY Mode
9 = Momentary arm in AWAY Mode
10 = Momentary disarm from AWAY Mode or STAY Mode
12= Momentary arm and disarm in STAY Mode
13 = Momentary arm in STAY Mode
14 = Momentary disarm from STAY Mode
Location
Option
0379
1 – 15 = Number of times siren operates
until lockout
Quick Reference Guide
Programming Parameters | en
8 = 20 sec.
9 = 30 sec.
10 = 40 sec.
11 = 50 sec.
12 = 60 sec.
13 = 90 sec.
14 = 120 sec.
15 = 200 sec.
Default
3
2
New
2014.06 | 02 | F01U298027

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Icp-sol3-p

Table of Contents