Error messages and troubleshooting
5.2 Error messages
Error code
(B#16#...)
50
Flashing of
ERR LED
08
8x
CRC sending error
•
09
9x
Only during initialization: CRC error when receiving an
acknowledgment from tag
•
0A
10x
Only during initialization: Tag cannot execute the initialization
command.
•
0B
11x
MOBY U: Memory of the tag cannot be read correctly
0C
12x
The tag memory cannot be written to
•
•
0D
13x
Address error
The address area of the tag is exceeded.
•
•
•
0E
14x
reserved
0F
1x
Startup message from CM. The CM was off and has not yet received a
RESET command.
•
•
10
16x
Note:
The NEXT command is not supported by the readers (MOBY U/D,
RF200 and RF300).
11
17x
Short-circuit or brief undervoltage of the 24 V supply of the CM or
overload of the 24 V outputs (error code, presence)
•
•
•
•
The tag is signaling CRC errors frequently.
–
The tag is in the boundary area of the reader.
–
The tag and/or reader have a hardware fault.
Cause same as error B#16#06.
Tag is defective
Tag memory is defective
The EEPROM memory of the transponder has been written to too
often and must be replaced
The start address in command_DB is invalid at command start (see
Section "Processing data memories")
The tag is not the right type
RF300: Attempted write access to write-protected areas (OTP
area)
Execute an init_run
The same physical CM channel is used in two (or more) UDT 10
structures. Check ASM_address and ASM_channel in all UDT 10
structures.
The affected output is turned off.
All outputs are turned off when total overload occurs.
A reset can only be performed by turning the 24 V voltage off and
on again.
Then start init_run.
Function Manual, 07/2012, J31069-D0166-U001-A4-7618
Description
FB 45 for MOBY U, MOBY D, RF200, RF300