3.1.1

INPUT parameters

Table 3- 2
INPUT parameter for MOBY D, MOBY U, RF200 and RF300
Variable
ASM_address
Logical base address of the CM; this address must match the "start address" of the CM in HW
Config of the SIMATIC Manager. Remember that this address has nothing to do with the PROFIBUS
address that is set on the CM or the ET 200M.
ASM_channel
Number of the MOBY channel which is to be used
ASM 475, 456; RF170C, RF180C
command_DB_
Number of the data block in which the tag command is specified
number
command_DB_
Address within the "command_DB". The next tag command starts
address
at this address. "command_DB_number" and
"command_DB_address" form a data pointer to the next
command (see Section "Configuration scheme").
Please note:
The input parameters command_DB_number and command_DB_address can be changed only
when ready = 1. An init_run does not need to be executed after changing these parameters.
MDS_control
MDS_control turns on/off the presence check or the tag control on the CM (see section "Presence
check and tag control").
Value
ECC_mode
reserved
RESET_long
MOBY U/D, RF200 and RF300 = 1
MOBY_mode
Setting the mode of the Ident system
Value
Please note:
MOBY_mode may only be changed after a CM is turned on.
FB 45 for MOBY U, MOBY D, RF200, RF300
Function Manual, 07/2012, J31069-D0166-U001-A4-7618
CM type
0
Presence check is off. The variable ANZ_MDS_present does not
indicate a valid value.
1
Presence check is on. MDS control is off. The variable
ANZ_MDS_present indicates a tag in the transmission window of a
reader.
Operating mode
0
reserved
1
reserved
5
MOBY U/D, RF200 and RF300 - without multitag
handling
6
reserved for multitag handling (FB 55)
7
reserved for multitag handling (FB 55)
Description
1, 2
Tag / transponder control
Parameterizing
3.1 Parameter data block
Value range
These INPUT parameters can
be changed whenever
ready = 1. An init_run does not
need to be executed after
changing these parameters.
CM type
Note
reserved for the setting with the
switch or GSD parameter
assignment
Short init_run (only the MOBY_mode
and option1 parameters are
transferred to the reader).
475; 456; RF170C, RF180C
(see description of FB 55)
(see description of FB 55)
all
all
21