(Ip 265 Viewpoint); Actual Addresses Of The Input And Output Parameters - Siemens SIMATIC S5 Manual

Ip 265 high speed sub control
Hide thumbs Also See for SIMATIC S5:
Table of Contents

Advertisement

IP 265
5.1.2

Actual Addresses of the Input and Output Parameters

(IP 265 Viewpoint)

Note
The actual addresses of the input and output parameters of the IP 265 are slot-
independent in the IP 265 user program.
The addresses (direct addressing) are used for addressing the parameter area of a maximum of 6
bytes for input parameters and 6 bytes for output parameters.
Table 5-2. Addresses of the Input Parameters
in the IP 265 User Program
Possible
Input Parameters
Count, time value
Bit input parameter
Table 5-3. Addresses of the Output Parameters
in the IP 265 User Program
Possible Output
Parameters
Count
Bit output parameter
In Section 5.3, you will find the assignment of the parameter addresses in the IP 265 user program
to the parameter addresses in the CPU user program.
EWA 4NEB 812 6130-02a
Direct Addressing in the
Data
IP 265 User Program
Type
(Slot-Independent)
10 bit
IW x. ;
count,
10 bit
time
value
Bit
I x.y
;
Direct Addressing in the
Data
IP 265 User Program
Type
(Slot-Independent)
10 bit
QW x. ;
count
Bit
Q x.y ;
x (66, 68, 70)
x (66 to 71)
y (0 to 7)
x (66, 68, 70)
x (66 to 71)
y (0 to 7)
Addressing
5-3