Regulations; Regulations For Gas Systems; Duty To Obtain A Permit And Provide Notification; Validity Of Regulations - Bosch Condens 7000 F Installation And Maintenance Instructions For The Contractor

Gas-fired condensing boiler
Hide thumbs Also See for Condens 7000 F:
Table of Contents

Advertisement

Unit
Height H
mm
AKO
Height H
mm
EL
Height H
mm
RLU
Height H
mm
1340
VK
Height H
mm
RK
Height H
mm
1520
VSL
Height H
mm
1570
GAS
Length L
mm
Length L
mm
K
1) Right-hand version
2) Left-hand version
3) Female thread (Table 7, page 18)
4) PN6 standard flange, EN1092 (Table 7, page 18)
Table 3 Measurements and connection dimensions
3

Regulations

DANGER:
Failure to comply with instructions may result in material damage
and personal injury, including danger to life!
▶ Comply with all instructions.
NOTICE:
Risk of system damage due to differing operating conditions!
Faults may arise if the specified operating conditions are disregarded.
Where there is serious disregard for the stated operating conditions,
individual components or the boiler itself may be destroyed.
▶ Observe the binding information on the data plate.
3.1

Regulations for gas systems

In order to ensure installation and operation of the product in
accordance with the regulations, please observe all the applicable
national and regional regulations as well as all technical rules and
guidelines.
The document 6720807972 contains information about the applicable
regulations. You can use the document search on our website to display
this. You will find the address of the website on the back of these
instructions.
3.2

Duty to obtain a permit and provide notification

Prior to installation of the heating and flue system:
▶ Inform relevant building authority.
▶ If required by the Clean Air Act 1993, seek approval for the flue
system from the Local Authority. For additional guidance see IGE/UP/
10 edition 4.
▶ Make sure that there are no concerns on the part of the authority
regarding the planned installation
▶ Make sure that official requirements are complied with.
▶ Please note that in certain regions approvals may be required for the
flue system and the connection of the condensate outlet to the public
sewerage system.
Condens 7000 F – 6720871560 (2019/11)
1)
2)
1)
75
75
100
100
257
257
257
257
455
455
455
455
176
176
176
176
1340
1340
1340
554
554
554
554
1520
1520
1520
1570
1570
1570
736
736
736
736
594
594
594
594
Boiler size (output in kW)
2)
1)
2)
1)
150
150
200
177
177
177
177
280
177
163
163
163
1343
1343
1343
552
552
552
1520
1520
1520
1620
1620
1620
914
914
1317
845
845
1250
3.3

Validity of regulations

Modified regulations or supplements are also valid at the time of
installation and must be observed.
3.4

Notes on installation and operation

Use only genuine spare parts from the manufacturer. The manufacturer
can assume no liability for damage caused by spare parts not supplied by
the manufacturer.
When installing and operating the heating system, observe the following
requirements:
• The local building regulations regarding installation conditions.
• The local building regulations regarding the supply and exhaust air
systems, and the chimney connection.
• Latest edition of the IEE Wiring regulations governing electrical
connection to the mains power supply
• Regulations and standards regarding the safety equipment in water-
filled heating systems. For guidance see the ICOM water treatment
guide for commercial heating systems.
• Make sure that the regional approvals required for the flue system
and condensate connection to the public sewage system have been
obtained.
2)
1)
2)
200
250
250
300
177
177
177
177
280
177
280
177
163
163
163
163
1343
1343
1343
1343
552
552
552
552
1520
1520
1520
1520
1620
1620
1620
1620
1317
1317
1317
1317
1250
1250
1250
1250
Regulations
1)
2)
300
177
280
163
1343
552
1520
1620
1317
1250
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents