Pressure classification to be used
for flue in accordance with EN 1443
Pressure classification to be used
or connection piece in accordance with EN 1443
Condensate resistance classification to be used for
flue system in accordance with EN 1443
Corrosion resistance classification to be used
for flue system in accordance with EN 1443
Soot combustion resistance classification to be used for
flue system in accordance with EN 1443
Maximum permitted flue gas return flow under wind conditions
Maximum permitted combustion air temperature
Type (according to DV/GW regulations)
Type (Belgium and Netherlands)
Electrical Wiring Specifications
IP rating
Supply voltage/frequency
Electric power consumption [P(el)]
Protection against electrocution
Maximum permissible unit fuse protection (with CC 8313)
Maximum permissible unit fuse protection (with MX25)
Appliance dimensions and weight
Handling dimensions width × depth × height
Total weight
Weight (excl. casing)
Smallest shipping weight
1) The details [xxx] correspond to the symbols and formula signs used on the data plate.
2) The load indicated on the display corresponds to the percentage fan speed and not the percentage modulation.
3) Is to be ensured by means of system sizing, and it corresponds to a minimum differential between flow and return temperatures of 8 K.
4) Nominal Co
value with nominal gas load, differences can arise depending on the quality of the gas available locally (Chapter 7.11, page 28).
2
5) Satisfies NO
class 6 in accordance with EN15502-1.
x
Table 19 Technical Data
Condens 7000 F – 6720871560 (2019/11)
Unit
75-3
H1, P1
H1, P1 with additional mechanical impact stability up to 5000 Pa
W
min. 2
G, O
%
10
°C
35
Balanced flue operation: C
IPX0D
V/Hz
230/50
Full Load
W
83
Partial load
W
28
A
10
A
6.3
mm
640x481x1470
kg
132
kg
105
kg
97.5
Boiler size (output – no. of sections)
100-3
150-4
200-5
H1, P1
H1, P1
H1, P1
W
W
W
min. 2
min. 2
min. 2
G, O
G, O
G, O
10
10
10
35
35
35
Open flue operation: B
Balanced flue operation: C
, C
, C
13
33
Open flue operation: B
, C
, C
, C
(not valid for Belgium), C
13
33
53
63
IPX0D
IPX0D
IPX0D
230/50
230/50
230/50
156
250
234
28
40
42
Protection class 1
10
10
10
6.3
6.3
6.3
640x782x
1470
132
184
231
105
139
175
97.5
118.3
148
Appendix
250-6
300-7
H1, P1
H1, P1
W
W
min. 2
min. 2
G, O
G, O
10
10
35
35
23P
, C
, C
, C
53
63
83
93
23P
, C
83
93
IPX0D
IPX0D
230/50
230/50
298
336
41
48
10
10
6.3
6.3
640x994x1470
258
283
214
239
175
200
57