5.
Raise the loader arms while tilting back the
mount plate at the same time.
Important:
Raise the attachment enough to
clear the ground and tilt the mount plate all
the way back.
6.
Shut off the machine and remove the key.
7.
Engage the quick-attach pins, ensuring that they
are fully seated in the mount plate
Important:
If the pins do not rotate to the
engaged position, the mount plate is not
fully aligned with the holes in the attachment
receiver plate. Check the receiver plate and
clean it if necessary.
Figure 11
1. Quick-attach pins
(engaged position)
2. Disengaged position
WARNING
If you do not fully seat the quick-attach
pins through the attachment mount plate,
the attachment could fall off the machine,
crushing you or bystanders.
Ensure that the quick-attach pins are fully
seated in the attachment mount plate.
(Figure
11).
g003711
3. Engaged position
Connecting the Hydraulic Hoses
WARNING
Hydraulic fluid escaping under pressure can
penetrate skin and cause injury. Fluid injected
into the skin must be surgically removed
within a few hours by a doctor familiar with
this form of injury; otherwise, gangrene may
result.
• Ensure that all hydraulic-fluid hoses
and lines are in good condition and all
hydraulic connections and fittings are tight
before applying pressure to the hydraulic
system.
• Keep your body and hands away from
pinhole leaks or nozzles that eject
high-pressure hydraulic fluid.
• Use cardboard or paper to find hydraulic
leaks; never use your hands.
CAUTION
Hydraulic couplers, hydraulic lines/valves,
and hydraulic fluid may be hot. If you contact
hot components, you may be burned.
• Wear gloves when operating the hydraulic
couplers.
• Allow the machine to cool before touching
hydraulic components.
• Do not touch hydraulic fluid spills.
If the attachment requires hydraulics for operation,
connect the hydraulic hoses as follows:
1.
Shut off the machine and remove the key.
2.
Move the auxiliary-hydraulics lever forward,
backward, and back to the N
relieve pressure at the hydraulic couplers.
3.
Remove the protective covers from the hydraulic
connectors on the machine.
4.
Ensure that all foreign matter is cleaned from
the hydraulic connectors.
5.
Push the attachment male connector into the
female connector on the machine.
Note:
When you connect the attachment male
connector first, you relieve any pressure built
up in the attachment.
6.
Push the attachment female connector onto the
male connector on the machine.
7.
Confirm that the connection is secure by pulling
on the hoses.