Connecting Trunks

Connecting Trunks

Connecting Analog Trunks

Each 8ATRU PCB connects 8 loop start CO trunks. Each 4ATRU PCB connects 4 loop start CO trunks.
To connect analog trunks (Figure 3-2):
1.
Using Figure 2-13 Connecting Trunks on page 2-11 as a guide, insert the mod jacks into the appropri-
ate connector on the PCB.
2.
For each trunk, run one pair cross-connect wire between the pins on the cross-connect block and the
CPE (customer side) of the telco's RJ21X.
3.
Install bridging clips as required.
3-2
Section 3: Installing Extensions and Trunks
One-Pair
Cross Connect
Telco
"A"
RJ21X
Block
25-Pair
Installation Cable
(P/N 80892)
Figure 3-2: Connecting Analog Trunks
25-Pair Cable
to Central Office
DS2000 Hardware Manual