Components Used - Siemens SINAMICS G120 Application Description

Sinamics g: speed control of a (startdrive) with (to) via profinet or profibus with safety integrated (via terminal) and hmi
Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

2 Solution
2.4 Hardware and software components
2.4.2

Components used

The application was created with the following components:
Hardware components when using PROFINET
Table 2-2
Component
CPU 1516- 3PN/DP
SIMATIC S7 Memory
Card
4MB
SIMATIC Panel,
KTP600 Basic color
PN
PROFINET
connector
PROFINET cable
SINAMICS G120
Motor
1
In this case, you have to customize the sample program.
SINAMICS G120 as a Speed Axis on the S7-1500
V1.0a, Entry ID: 78788716
Qty.
Order no.
1
6ES7516-3AN00-0AB0
1
6ES7954-8LC01-0AA0
1
6AV6647-0AD11-3AX0
6
6GK1901-1BB10-2AA0
6XV1840-2AH10
1
G120:
CU 240E-2 PN
6SL3244-0BB12-1FA0
CU 240E-2 PN-F
6SL3244-0BB13-1FA0
PowerModule:
6SL3224-0BE17-5UA0
G120C PN:
6SL3210-1KE18-8AF1
G120D:
CU240D-2 PN
6SL3544-0FB20-1FA0
CU240D-2 PN-F
6SL3544-0FB21-1FA0
Power module:
6SL3525-0PE17-5AA1
G120P
CU230P-2 PN
6SL3243-0BB30-1FA0
Power module:
6SL3224-0BE17-5UA0
1
1LA7063-4AB12
Note
Alternatively, any other S7-
1
1500 CPU can be used.
Alternatively, any other
SIMATIC S7 Memory Card
can be used.
Or other operator panel or
simulation/runtime.
The panel is optional.
To connect the S7 CPU to the
panel and the PG/PC.
Sold by the meter (20 to
2000m).
Alternatively, any other
SINAMICS G120C PN, G120
or G120D with PROFINET-
1
capable CU can be used.
Alternatively, any other motor
suitable for the used
SINAMICS G120 converter
1
can be used.
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic s7-1500Step 7 v12 sp1 upd2Startdrive v12 sp1

Table of Contents