6.3 For Use on Remote I/O Network

6 - 6
System configuration used in the program explanation
(1)
System configuration
Remote master station (Network No.1)
Power
Q
Q
n
J
supply
C
7
module
P
1
U
L
P
2
1
Perform the following intelligent function module switch settings in advance.
• Switch 1
0030
• Switch 2
Empty
• Switch 3
0000
• Switch 4
0000
• Switch 5
0000
(2)
Program conditions
The digital values of CH1 and CH2 of the Q62DA-FG are written and their output
monitor values are read to the programmable controller CPU of the remote
master station.
If a digital value write error occurs, the corresponding error code is displayed in
BCD.
(a)
Initial settings
• Analog output enabled channel .................... CH1, CH2
• Rate control enabled channel ....................... CH1 (increase digital limit
• Disconnection detection enabled channel ... CH1
• Warning output enabled channel .................. CH2 (warning output upper
(b)
Devices used by user
• Initial setting request signal ..................................... X20
• Output enable ........................................................... X21
• Digital value write signal .......................................... X22
• Disconnection detection reset signal ....................... X23
• Warning output reset signal ..................................... X24
• Error code reset signal ............................................. X25
• Error code display (BCD 3 digits) ............................ Y30 to Y3B
• CH1 Digital value ..................................................... W11
• CH2 Digital value ..................................................... W12
• CH1 Output monitor value ....................................... W113
• CH2 Output monitor value ....................................... W114
• Disconnection detection flag .................................... W115
• Warning output flag .................................................. W116
• Error code ................................................................. W117
• Disconnection detection channel flag ...................... M10
• Warning output channel flag .................................... M22, M23
Q
Q
X
Y
1
1
0
0
(CH1: 4 to 20mA, CH2: 0 to 5V)
H
(CH1, CH2: Clear)
H
(Normal mode (D/A conversion processing))
H
(0: Fixed)
H
Remote I/O station (Station No.1)
Power
Q
Q
Q
J
X
Y
supply
7
1
1
module
2
0
0
L
P
2
5
X/Y100
X/Y110
to
to
X/Y10F
X/Y11F
value: 100, decrease digital
limit value: 30)
limit value: 10000, warning
output lower limit value: 3000)
MELSEC-Q
Q
6
2
D
A
F
G
X/Y120
to
X/Y12F
6 - 6