PS5000 Environmental Requirements
You must meet these environmental requirements:
•
Only operate an enclosure from a power source with a voltage range of 100 to
240 VAC.
•
Make sure each power source has sufficient electrical overload protection.
•
Have sufficient space for air flow in front of and behind the array.
•
Make sure the location is properly vented.
•
Follow the PS5000 technical specifications shown in Table 2-2.
Table 2-2: PS5000 Technical Specifications
Component
Weight of fully-loaded array
Operating temperature
Storage temperature
Maximum operating altitude
Operational relative humidity
Thermal output (fully-loaded array) 1700 BTU/hour (SAS disks)
Operational shock
Operational vibration
Input voltage
Input frequency
System input power
Height/Width/Depth
Each power supply
2–4
Requirement
77.6 pounds or 35 kilograms
41 to 95 degrees F / 5 to 35 degrees C
-22 to 140 degrees F / -30 to 60 degrees C
10,000 feet (3048 meters)
20 to 80% non-condensing
1550 BTU/hour (SATA disks)
5 G for 10 ms 1/2 sin
Random 0.21grms 5 - 500 Hz
100 to 240 VAC (auto-sensing)
48 - 62 Hz
530 VA (maximum)
5.12" x 19" x 21.7" (13 x 48.26 x 55.1 cm)
450 watts DC output
Maximum input power: 0.7 KVA
Input current: 7 – 3.5A
Installing Array Hardware