Ps5000 Rack Mount Requirement; Installing The Ps5000 Hardware - Dell EqualLogic PS Series Installation And Setup

Storage arrays
Hide thumbs Also See for EqualLogic PS Series:
Table of Contents

Advertisement

Installation and Setup
Optional hardware you can use with an array is described in Table 2-5.
Table 2-5: Optional Hardware – Not Supplied
Component
Uninterruptible power
supply (UPS) systems

PS5000 Rack Mount Requirement

A PS5000 array must be mounted in a standard, 19" rack. The rail assembly kits
supplied in the array shipping box include installation and mounting instructions.
Supplementary instructions for a four-pole rack are included in the shipping box.
You must adhere to the following array racking requirements:
Mount the array in a horizontal position. Otherwise, you will void your array
warranty and support contract.
Attach the rack to the floor for added stability.
Support the array until it is completely mounted in the rack.

Installing the PS5000 Hardware

After you complete the preliminary tasks described in Before You Begin to Install
a PS5000 on page 2-3, follow these steps:
1. Connect the power cables. Do not turn on power to the array at this time. See
Step 1: Connect the PS5000 to Power on page 2-8.
2. Connect the array to the network. See Step 2: Connect the PS5000 to the
Network on page 2-9.
3. Turn on power to the array. See Step 3: Turn on Power to the PS5000 on
page 2-11.
4. If you plan to use the Remote Setup Wizard to configure the software, skip
this step.
If you plan to use the
Up a Serial Connection to the PS5000 on page 2-11.
Description
Provides a highly available source of power to an array. Each
UPS system should be on a different circuit and must provide the
correct type of voltage for an adequate amount of time.
utility to configure the software, see Step 4: Set
setup
Installing Array Hardware