Mitsubishi Electric MELSEC- iQ-R Series Startup User's Manual page 45

Channel isolated analog-digital converter module
Hide thumbs Also See for MELSEC- iQ-R Series:
Table of Contents

Advertisement

Current input characteristics
The following shows the list of analog input ranges at the current input and the graphs of each of the current input
characteristics.
digit
32767
32000
0
-768
-32000
-32768
-40
-20
digit
32767
32000
0
-8000
-8768
-32000
-32768
-40
-20
digit: Digital output value
(3) (16bit): The line shows (3) for 16 bit.
(3) (32bit): The line shows (3) for 32 bit.
(a): Practical analog input range
No.
Analog input range setting
(1)
4 to 20mA
(2)
0 to 20mA
(3)
4 to 20mA (extended mode)
(a)
(1)
4
0
20
40 mA
(a)
(3)
(3)
(16bit)
4
0
20
40
mA
22.00
Offset value
Gain value
4mA
20mA
0mA
20mA
4mA
20mA
digit
32767
32000
0
-768
-32000
-32768
-40
-20
digit
36767
36000
32000
0
-8000
-8768
-32000
-32768
-40
-20
Digital output value
0 to 32000
-8000 to 36000
Appendix 1 I/O Conversion Characteristics
(a)
(2)
0
20
40 mA
(a)
(3)
(32 bit)
4
0
20
40
mA
22.00
*1
Resolution
500.0nA
625.0nA
500.0nA
APPX
A
43

Advertisement

Table of Contents
loading

Table of Contents