 Ethernet model
Sink logic
Main circuit terminal
Control circuit terminal
Single-phase power input
MCCB
Single-phase
AC power
supply
MCCB
Three-phase
AC power
supply
Control input signals (No voltage input allowed) 
Forward
rotation start
Reverse
rotation start
Contact input common
24VDC power supply(Common for
external power supply transistor)
Safety stop input common
Safety stop input (Channel 1)
Safety stop input (Channel 2)
Frequency setting signals (Analog)
Frequency
setting
potentiometer
1/2W1kΩ

Terminal 4 input
(Current input)
Connector for
plug-in option connection
*1
Remove the jumper between P1 and P/+ to connect the DC reactor.
*2
The function of these terminals can be changed using the Input terminal function selection (Pr.178 to Pr.179). (Refer to the FR-E800 Instruction
Manual (Function).)
*3
The initial setting varies depending on the specification.
*4
Terminal input specifications can be changed by analog input specification switchover (Pr.73, Pr.267). To input voltage, set the voltage/current
input selection switch to "V". To input current, set the switch to "I". The initial setting varies depending on the specification. (Refer to the FR-E800
Instruction Manual (Function).)
*5
It is recommended to use 2 W 1 kΩ when the frequency setting signal is changed frequently.
*6
The FR-E820-0008(0.1K), FR-E820-0015(0.2K), FR-E820S-0008(0.1K), and FR-E820S-0015(0.2K) are not equipped with brake transistors.
*7
Brake resistor (FR-ABR, MRS, MYS)
Install a thermal relay to prevent overheating and damage of brake resistors. (A brake resistor cannot be connected to the FR-E820-0008(0.1K),
FR-E820-0015(0.2K), FR-E820S-0008(0.1K), and FR-E820S-0015(0.2K).) (Refer to
*8
The function of these terminals can be changed using the Pr.192 ABC terminal function selection.
DC reactor
MC
(FR-HEL)
R/L1
S/L2
Earth
(Ground)
Jumper
MC
P1
R/L1
S/L2
T/L3
Earth
(Ground)
Control circuit
DI0
DI1
SOURCE
SD
PC
S1
Output
S2
shutoff
Shorting wire
circuit
10(+5V)
3
2 0 to 5VDC
2
0 to 5VDC
0 to 20mADC
5(Analog common)
1
4 4 to 20mADC
(+)
0 to 5VDC
(-)
0 to 10VDC
2
V
I
4
Voltage/current

input switch
Option connector
Brake unit
(Option)

R

PR N/-

P/+
V
W
Main circuit
C
B
Relay output
(Fault output)
A
SINK
SINK

SOURCE
24V
SO
Safety monitor output
SOC
Safety monitor output common
Ethernet
connector
Ethernet

connector
USB mini B
connector

page
81.)
Motor
M
Earth (Ground)
Relay output 
Safety stop signal
2. Installation and Wiring
2.4 Terminal connection diagrams
1
2
3
4
5
6
7
8
9
10
41

Advertisement

Table of Contents
loading