WARNING
Usage
 Stay away from the equipment after using the retry function in this product as the equipment will restart suddenly after
the output shutoff of this product.
 Access to the motor is allowed only after it is fully confirmed that the motor does not start running.
 Depending on the function settings of this product, the product does not stop its output even when the STOP/RESET
key on the operation panel is pressed. To prepare for it, provide a separate circuit and switch (to turn OFF the power of
this product, or apply a mechanical brake, etc.) for an emergency stop.
 Be sure to turn OFF the start (STF/STR) signal before clearing the fault as this product will restart the motor suddenly
after a fault is cleared.
 Do not use a PM motor for an application that the motor may be driven by the load and run at a speed higher than the
maximum motor speed.
 Use only a three-phase induction motor or PM motor as a load on this product. Connection of any other electrical
equipment to the output of this product may damage the equipment.
 Performing pre-excitation (LX signal and X13 signal) under torque control may start the motor running at a low speed
even when the start signal (STF or STR) is not input. This product with the start command ON may also rotate the motor
at a low speed when the speed limit value is set to zero. Confirm that the motor running does not cause any safety
problems before performing pre-excitation.
 Do not modify this product.
 Do not remove any part which is not instructed to be removed in the Instruction Manuals. Doing so may lead to a failure
or damage of this product.