Pre-Assembled Power Cables - Siemens SINAMICS S120 Manual

Power units in booksize c/d-type format
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Now insert coding keys into the matching slots on the motor connector terminal. In order to prevent the connector with
coding key
from being inserted into the left-hand connector terminal, a coding key must be inserted into the matching
slot
of this terminal. Insert a coding key into the uppermost slot
The connector with coding key
connector and terminal with coding keys
4.1.5.4

Pre-assembled power cables

Description
The pin assignments of the pre-assembled power cables are as follows:
Cable
U2
V2
W2
Protective conductor connection (PE)
Holding brake BR+
Holding brake BR-
Power Units in Booksize C/D-Type Format
Manual, 12/2018, 6SL3097-5AC20-0BP0
is now only compatible with the terminal with coding key
and
.
Motor connection, shield support and fabrication
4.1 Motor plug connector for Motor Modules 3 A ... 30 A
of the right-hand connector terminal.
Color
Black
Black
Black
Green/yellow
Black
White
. The same applies to the
Labeling
U/L1
V/L2
W/L3
-
-
-
85