Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix E: Pulse Output
.

Appendix E: Pulse Output

Table 103 to Table 111 vary depending on the account number specified and the digit
parameter programmed using the drop-down menus in Menu Item 3.1.7 Event 3/1 or 4/1
(Figure 27).
The output of the receiver depends on the reporting digit. Use the settings in Figure 27 that can be
changed by the user:
Reporting digits 0 to 9 and A are alarms
Reporting digit B is an opening
Reporting digit C is a closing
Reporting digit D is a cancel
Reporting digit E is a restore
Figure 27:
D6200 Receiver Software Line Card Configuration
Table 103:
Pulse 3/1 Format
#
Event
Account
Number
1. ALARM
123
2. OPENING
123
3. CLOSING
123
Bosch Security Systems, Inc. | 2012.09 | 4998122703-05
Reporting
Device/Mode
Digit
4
Printer:
D6500 Mode:
SIA Mode:
B
Printer:
D6500 Mode:
SIA Mode:
C
Printer:
D6500 Mode:
SIA Mode:
Displays
DD/DD TT:TT L01 ACCT
[10]1011sssssss123sAsss4[13]
[10]602415[9]00030101[#s123|NBA4][13]
DD/DD TT:TT L01 ACCT
[10]1011sssssss123sOssss[13]
[10]AA4214[9]00040101[#s123|NOP][13]
DD/DD TT:TT L01 ACCT
[10]1011sssssss123sCssss[13]
[10]F94B14[9]00050101[#s123|NCL][13]
123 ALARM_ZN 4
123 OPENING
123 CLOSING