Bosch Conettix D6600 Manual page 33

Computer interface of receiver/gateway
Table of Contents

Advertisement

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
Optional Silent Knight SK1 (Message Type m):
If Menu Item 2.5.16 in the D6600/D6100IPv6/D6100i Receiver is equal to 1, the following output
is used.
Silent Knight
D6500 Byte Description
FSK1 Example
1
2
h
m
Table 30: Optional Silent Knight SK1 (Message Type m) Byte Description
#
Title
1
Header
Character (h)
2
Message Type
3-4
Receiver
Number
5
Line/Group
Number
6
Spaces
7-14
Account
Number
15
"
16-17
ZZ
18
"
19
***
21
Trailer
Character
Bosch Security Systems, Inc. | 2012.09 | 4998122703-05
3
4
5
6
7
8
r
r
l
s
a
a
Description
Optional. Check with the computer automation software for
compatibility.
m
Receiver gateway number from 01 to 99.
Line number in the receiver gateway that sent the message.
One space.
Maximum eight-digit account code. If the account code is less than
eight digits, enter the actual number of digits without a leading space.
Separator.
First zone number, up to eight reports, one report has two digits.
Separator.
More data.
Typically, HEX 14.
9
10 11 12 13 14 15 16 17 18 19
a
a
a
a
a
a
"
Z
Z
"
. . .
21
t
33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Conettix d6100ipv6Conettix d6100i

Table of Contents