Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
3.2.10 Common Formats (Message Type <TAB>)
Defined
SIA Mode Description
Messages SIA
<LF><CRC><TAB><sequence#><receiver#><line#>[#aaaaaaaaaaaaaaaa|data]<CR>
Example
Table 56: Common Formats (Message Type <TAB>) Byte Description
Title
LF
CRC
Message Type
sequence#
receiver#
line#
(Line/Group #)
account#
Data
The receiver gateway sends the 3-1, 4-1, 4-2, single round, double round, extended pulse formats,
BFSK, Modem II or Modem IId messages in either D6500 Mode or SIA Mode, depending on the
program option selected. The receiver gateway also sends internal and ModemIIIa² messages in either
D6500 mode or SIA mode, depending on the programmable option selected. Refer to Appendix B:
Internal Messages and Appendix C: Modem4/ModemIIIa² for a list of the messages and their
descriptions.
Figure 14: Message sent to printer
MM/DDsHH:MMsLxxSIA ACCT aaaa
+++ TEXT 1
+++ TEXT 2
Bosch Security Systems, Inc. | 2012.09 | 4998122703-05
Description
Standard line feed character.
Cyclical Redundancy Check number.
09 hex <TAB>
The message sequence number. The valid sequence number range is
0001 to 9999.
The receiver gateway that sent the message. Valid digits are 01 to 99 for
the D6600/D6100/D6100IPv6.
The line number of the line in the receiver gateway that sent the
message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for
internal messages.
The communicator's account number up to sixteen digits.
This field contains message data codes such as event type, area number,
point number, identification number, and so on.