Fm-Stepdrive And Simostep Wiring - Siemens SIMATIC SIMOSTEP 1FL3041 Functional Description

Fm-stepdrive power controller; 3-phase stepping motors
Table of Contents

Advertisement

6 Wiring
6.1

FM-STEPDRIVE and SIMOSTEP wiring

Mains/intermediate
circuit connection
115 VAC
or
Fuse
230 VAC
L
Mains
N
PE
Figure 6-1 FM-STEPDRIVE and SIMOSTEP wiring
!
6-2
Wire the FM-STEPDRIVE power controller and the SIMOSTEP series
motor in accordance with figure 6-1.
FM-STEPDRIVE
DC
+
DC
-
115
230
filter
N
PE
MS
SIMOSTEP motor
Shield connection
Motor cable gland
Danger
The supply voltage must be disconnected whenever wiring work is carried
out. When the supply voltage is connected, high voltages are present on
the mains, intermediate circuit and motor connections. Never touch these
connections when the unit is switched on, since this constitutes a danger
of death or severe injuries.
Pulse interface
PULSE_N
DIR_N
ENABLE_N
PWM_N
GND
GND
READY1_N
15
Signal interface
U
V
W
PE
Schild connection
as short as possible
5
6
4
7
8
(W )3
9
(V) 2
0
(U) 1
PE
© Siemens AG 1998 All Rights Reserved
1
PULSE
DIR
ENABLE
Control unit
PWM
GND
GND
Not used
GND
Supply
L+ (24 V)
M (24V GND)
GATE_N
ENABLE_N
Control unit
MSTILL
ZERO
READY2
Motor connection
U
V
W
Shield connection
Strain relief spring
Shield connection
Mounting plate
FM-STEPDRIVE/SIMOSTEP (FB)
02.05
24 V

Hide quick links:

Advertisement

Table of Contents
loading