ALARM
Critical High Forward Power
Critical High Reflected Power
Critical High Input Air Temperature
High Input Air Temperature
Low RF Input Level
High RF Input Level
PA__ High Current
PA__ Critical High Current
PA__ Low Current
PA__ Unbalance Current
PA__ High Temperature
PA__ Critical High Temperature
PA__ Low Gain
ALARM DESCRIPTION
Power Amplifier Drawer forward output power is greater than
1300Watts.
Default system action: Shutdown.
Drawer reflected output power is greater than 184Watts.
Default system action: Shutdown.
Ambient air temperature used in the reflow of the equipment is
greater than 48°C (118,4ºF).
Default system action: Shutdown.
Ambient air temperature used in the reflow of the equipment is
greater than 35°C (95ºF).
Default system action: Notification.
RF Input Level is less than -8dBm
Default system action: Notification.
RF Input Level is greater than 10dBm
Default system action: Notification.
Current at the indicated PA is greater than 10A.
Default system action: Notification.
Current at the indicated PA is greater than 10A.
Default system action: Shutdown.
Current at the indicated PA is less than 0.2A.
Default system action: Shutdown.
Current in the indicated PA is 2.5A is higher or lower than the
others.
Default system action: Notification.
Temperature at the indicated PA is greater than 75ºC (167ºF).
Default system action: Notification.
Temperature at the indicated PA is greater than 80ºC (176ºF).
Default system action: Shutdown.
Indicated PA Gain is Less than 49dB.
Default system action: Notification