Signaling Leds - Hitachi E-Compact Medium Power Series Operation Manual

Uhf digital tv transmitters
Table of Contents

Advertisement

6.2.4. Signaling LEDs

Each Power Amplifier Drawer Features a LED bank that indicates the situation of its operation according
to the color As shown below::
Green
Normal operation.
Orange
Orange light indicates That a failure has occurred.
Red
Flashing Red light indicates an ongoing failure.
PWR
SHDN
FWD
RFD
PA
DRV
PSU
FAN/
TEMP
LED
ALARM
PWR
N/A - This LED lights only GREEN indicating that is POWERED ON.
SHDN
Power Supply Shutdown
FWD
Over Forward Power (Overdrive)
RFD
Reflected Power
PA Failure, High Current on PA, Low Current on PA, Current UNBAL on PA, Low
PA
Gain on PA, High Temperature on PA, Communication Failure on PA.
High Current on Driver, Low Current on Driver, Low Current on Pre Driver, High
Current on Pre Driver, Low Gain on Driver, High Temperature on Driver, Low
DRV
Voltage on Driver, Communication Failure on Driver, High Input Signal, High
Driver Output Level.
Low AC Line Voltage, High AC Line Voltage, Low PSU Voltage, High PSU Voltage,
PSU
High PSU Current, High PFC Temperature, High DC/DC Temperature, PSU
Communication Failure.
When detected slow speed of rotation or complete failure in any of the fans.
FAN/TEMP
High temperature input air of the power drawer (greater than 35ºC).
Alarm details are displayed by accessing the keyboard-display interface of the Control Module CM8001
in the menus:
⇨ Main Menu ⇨ System Alarms/Log [3000] ⇨ Drawers Alarms ⇨ Current Drawers Alarms [3310]
⇨ Main Menu ⇨ System Alarms/Log [3000] ⇨ Drawers Alarms ⇨ Past Drawers Alarms [3320]
E-Compact Medium Power
55 | 106

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ec702mpEc704mp