Equipment Assembly; Assembly - Hitachi E-Compact Medium Power Series Operation Manual

Uhf digital tv transmitters
Table of Contents

Advertisement

4. Equipment Assembly

Observe the requirements described in this manual in Sections 1 (Care, Warranty and
Service) and Section 2 (Minimum Installation Requirements).
The following precautions must be taken when positioning the transmitter at the installation site:
(1) The air intake (front) and the air outlet (rear) must be completely unobstructed.
(2) The transmitter rack should be positioned to ensure easy access from either side. The distance
between the transmitter and the walls of the shed must be at least 1.0 meter.
(3) In case of installation on a site containing other transmitters connected, do not position the
transmitter in a location that can receive hot air from other transmitters.

4.1. Assembly

(1) Unpacking the transmitter and drawers.
(2) Position the rack where the equipment is installed in compliance with the following issues:
Antenna cable
AC Power Supply
RF Cable
Transport Stream (ASI) cables
Grounding point
(3) Visual Inspection:
Remove the lateral and rear panel of the transmitter and proceed to a visual inspection searching
for any alteration that may have happened during the transportation of the equipment.
Pay special attention on the RF and signal cable connectors, ie. loose screws.
Check the power switches located on the left of the rear panel of the units, make sure they are in
the "ON" position.
(4) Grounding:
For personal and equipment safety reasons, connect the ground of the of the transmitter room to
the ground of equipment before proceeding to the next steps.
Only trained and trained personnel should conduct physical assembly on site.
E-Compact Medium Power
72 | 106

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ec702mpEc704mp

Table of Contents