4-2. Error Codes

This unit has a self diagnostics function which detects
internal abnormalities. When a problem is detected, an
error code is displayed immediately in the time counter
block, and details of the error appear on the video monitor
connected to the VIDEO OUT 3 (SUPER) or the SDI
OUTPUT (SUPER) connector.
n
An error code appears in the column shown by XX-XXX
on the display.
When detected, some errors turn the unit to AUTO OFF.
(Refer to Section "4-2-3. Error Codes," excluding error
code 08-032.)
This error is kept in memory even after the main power of
this unit is turned off. In other words, the error code or the
contents of the detected error appear even when the main
power of this unit is turned off and then back on again, so
this unit enters AUTO OFF mode again.
This unit enters the emergency EJECT mode when the
[EJECT] key is pressed at this moment.
[Reference]
In the emergency EJECT mode, the tape is ejected gently
by usable motor assuming that the tape is slack or a device
may be faulty.
The following message appears on the video monitor
connected to the VIDEO OUT 3 (SUPER) or the SDI
OUTPUT (SUPER) connector when this unit enters the
emergency EJECT mode.
The error code is displayed on the time counter.
DSR-2000A/2000AP
ERROR
AN ERROR HAS BEEN
DETECTED. I NFORM SERV I CE
OF FOLLOWING CODE :
XX-XXX
PRESS EJECT KEY
TO EJECT TAPE.
ERROR
TAPE I S BE I NG EJECTED.
WA I T UNT I L TH I S
I ND I CAT I ON GOES OFF.
4-3