5-3. Video Head Tip Protrusion Check
Setting of Head Tip Protrusion Measurement
Gauge
n
Being careful not to damage the tape-running surface and
video heads of the drum, set the gauge.
1. Turn the upper drum manually counterclockwise (3)
to align the screw hole to the rib of the threading ring
as shown in Figure 2.
n
The upper drum position is determined as described
above to put the probe of the head tip protrusion
measurement gauge on the absence of a head. The
video head that first measures the protrusion value is
the Y-A head.
2. Check the value that the dial gauge pointer reads.
3. Position a probe between the PB B2 head and dummy
head. (Refer to Figure 2.)
4. Press the tip of two legs against the outer circumfer-
ence of the drum's upper surface while keeping the
base plate of the measurement gauge in parallel with
the upper surface of the drum. Be sure to keep the
probe of the measurement gauge sufficiently away
from the drum.
5. Lower the measurement gauge slowly until the ridges
of the two legs and positioning flange touch the upper
drum while pushing two legs against the outer circum-
ference of the drum's upper surface (applying force
slightly to the measurement gauge in the direction
indicated by the arrow). (Refer to Figure 3.)
m
. Before placing a measurement gauge on the drum,
ensure that the adjustment screw has been loosened
fully.
. Perform carefully and slowly so that the probe of a
measurement gauge does not touch the outer circum-
ference or video head on the drum. (Lower so that
the probe is slightly higher than the two legs.)
. After placing the measurement gauge on the drum,
be sure to support it with hand at all time.
If it is loose carelessly, the drum and measurement
gause will turn and damage the peripheral parts.
6. Check to see the followings:
. The probe is in the middle of the adjacent heads.
. The positioning flange adheres closely to the outer
circumference of the drum's upper surface.
. The legs adhere closely to the outer circumference of
the drum's upper surface.
. The value that the dial gauge pointer reads is the
same as before setting (in step 2).
5-14
7. Turn the adjustment screw clockwise until the dial
gauge pointer rotates approximately a half turn.
8. Turn the outer frame of the dial gauge to align zero (0)
to the pointer.
Drum
Figure 2. Setting of Drum Position
Base plate
Leg
Screw hole
Leg
Drum
Figure 3. Setting of Head Tip Protrusion Measurement Gauge
Screw hole
PB B2 head
Rib
Dummy head
Adjustment screw
Dial gauge
A
Cover
Positioning
flange
Drum
Probe
DNW-A22/A22P