6-6. TBC-23 Board Replacement
Connection
Connect the waveform/vector monitor and video monitor as shown below.
VIDEO OUTPUT
COMPOSITE
2
1. Initial Data Setting
(1) Enter the maintenance mode, then enter A37 : TBC VR.
(2) Set the specified data to all items of A37 : TBC VR.
Item of A37 : TBC VR
SQ Y RZ
SQ C RZ
VISC PHASE
(3) To exit A37 : TBC VR, press the MENU button once.
(4) Data save
Enter A3F : NV-RAM CONTROL of the maintenance mode, then execute "SAVE ALL ADJUST
DATA".
(5) Check that the message "Save Complete" is displayed on the video monitor.
(6) To exit A3F : NV-RAM CONTROL, press the MENU button once.
(7) To exit the maintenance mode, press the MENU button three times again.
6-82
DNW
1
75 Z
Setting data for DNW-A22
4C
6F
06
Composite
waveform/vector
monitot
CH-A
Video monitot
(terminated
with 75 Z)
Setting data for DNW-A22P
4B
6E
02
DNW-A22/A22P