Magne 4 Ossd-Info - ABB Magne 3 Product Manual

Electromagnetic process lock
Table of Contents

Advertisement

5.6

Magne 4 OSSD-Info

Male and female M12 8-pole connectors seen from cable side.
M12 8-pole connector
1
White
2
Brown
3
Green
4
Yellow
5
Grey
6
Pink
7
Blue
8
Red
Warning! The info output is non-failsafe and shall never be used to control a safety
Warning! The safe OSSD signals are used to control the safety application.
Note!
2TLC172315M0201 Rev.M3
OSSD1 out
+24 VDC
OSSD1 in (+24 VDC for the first device after the safety control unit)
OSSD2 in (+24 VDC for the first device after the safety control unit)
Info output (Adam and Eva closed & Magne locked)
OSSD2 out
0 V
Locking signal +24 VDC
application.
Several Magne OSSD-Info units can be connected using a M12-3G
Y-connector, but the info-signal will not be available.
2 1